Interwoven mesh.
Diamond-pattern chain link infill, with wire diameter and mesh opening specified at order stage.

The chain link panel series
Temporary chain link fence panels.
Woven mesh, tubular frames and connected bases. Choose the format around your site.
Inside the panel
The diamond mesh is held within a tubular steel frame. Panel height, span and bracing distinguish the three formats; the bases and clamps complete the connection to the next panel.
Diamond-pattern chain link infill, with wire diameter and mesh opening specified at order stage.
Listed frame diameters run from Ø31.75 to Ø34.93 mm across the three panel models.
Choose a vertical-braced, cross-braced or taller dual-braced panel. Compare the actual dimensions below.

The three panel formats
Explore the panel as a whole. Select a format to see its construction, listed dimensions and frame diameter.

The widest listed panel in this series, with a central vertical member dividing the span.
Nominal format is the model name. Use the listed metric dimensions for your selection. Bases and clamps are separate line items.
The specification, side by side
| Panel specification | KC-TF-CL-P01Vertical-braced | KC-TF-CL-P02Cross-braced | KC-TF-CL-P03Dual-braced |
|---|---|---|---|
| Nominal format | 6′ × 12′ | 6′ × 10′ | 8′ × 10′ |
| Listed width × height | 3658 × 1798 mm | 2921 × 1829 mm | 3048 × 2438 mm |
| Frame tube diameter | Ø32 mm | Ø31.75 mm | Ø34.93 mm |
| Panel weight | 20.87 kg | To confirm* | 26.3 kg |
| Bracing | Central vertical member | Cross-braced · Ø25.4 mm brace | Dual-braced format |
| Wire / mesh opening | To confirm | To confirm | To confirm |
| Finish specification | To confirm by model | To confirm by model | To confirm by model |
*The P02 standalone panel weight and included components require confirmation. Metric dimensions are rounded from the listed product data; the nominal foot labels do not replace these dimensions. Images may show separately supplied bases.
Request a model quotationFrom one panel to the next
Specify the base and panel connection together. Match the frame interface, ground conditions and layout.

762 × 457.2 × 304.8 mm.
A tubular base with two upright receivers for the panel connection.

609.6 × 609.6 × 177.8 mm.
An alternative base format. Confirm fit and the supporting arrangement for the site.

Clamp brackets, carriage bolts and nuts for adjoining frames. The final set and quantities follow the selected panel.
Bases and connectors are requested as separate items unless the quotation explicitly includes them. Include opening widths and gate requirements in your layout; gate compatibility is confirmed with the complete system.

Material & finish
Start with the published panel geometry. Then specify the mesh, coating and site conditions with the selected model.
The three models have identified dimensions, frame diameters and bracing formats. The product descriptions specify galvanised steel tubing.
Confirm wire diameter, mesh opening, tube wall thickness and the coating specification. Hot-dip availability and weld treatment require model-level confirmation.
Include any coating colour, PVC/PE finish or screen requirements. Availability and the effect of screening on support design need review before ordering.
The site around the system
Consider the routes, surface and exposure alongside the panel specification.

Define the work boundary and the delivery openings. Include turning space, panel transitions and the ground surface in the layout.
Explore the applicationBefore you specify
Typical applications include construction boundaries, work zones, temporary storage yards and event perimeters. Share the intended use, pedestrian routes, access needs and exposure so the panel and support arrangement can be reviewed together.
The listed base formats use upright receivers for the panel frame. They provide a freestanding ground interface, but the complete support or anchoring arrangement depends on the surface, wind exposure and any screens. A base alone is not a site-specific stability assessment.
Compatible bases receive the adjoining panel frame tubes, with clamp hardware connecting the frames. Confirm tube fit, clamp set, connection positions and quantities in the supply schedule.
Specify the exposure, intended service conditions and required coating process. Galvanised tubing is described for the panels, while the exact galvanising route, wire finish and any PVC/PE option require confirmation for the model. No fixed corrosion life is stated here.
Record the ground surface, slope, exposure and any attached screen or signage. These inputs inform the support, ballast or anchoring review. Use the site assessment guide to prepare the information; do not assume a standard base arrangement fits every site.
Panels and removable bases can be planned as separate handling units. Agree bundle contents, stacking and protection, unloading arrangements and delivery destination with the order. Request the packing schedule for the selected model and quantities.
From panel choice to project scope
Bring the models, quantities and connections into one request. Add your location and the details that shape the installation.
Prepare an email draft or copy your requirements. Send from your email app, with your drawings or BOQ attached there.
Temporary Chain Link Fence Panels