How to Request a Quote for Temporary Fence Privacy Screens
Ask for the fabric, fixing method and screened-fence arrangement together. A fabric sample can confirm colour and coverage, while the fence design must account for the added wind load.

The Engineering Fact Behind Every Requirement
A screen adds wind load, and it adds more than its open area suggests. Wind codes account for porosity with a factor applied to the load on a solid surface of the same size.
Performance Requirements
| Item | What to specify |
|---|---|
| Material and construction | Knitted HDPE monofilament or tape; or PVC-coated polyester mesh; state which |
| Mass per unit area | g/m², with tolerance |
| Cover or shade factor | Per cent, with test method |
| Hems and reinforcement | Hem width, number of stitch rows or welded hem, webbing reinforcement |
| Eyelets | Material, inside diameter, spacing along each edge, pull-out strength |
| Size | Finished width and height matched to panel; tolerance |
| Colour and print | Colour reference; print method and ink durability |
Fixings and Tie Load
The force on the screen reaches the frame through the ties.
Requirements for fixings should therefore state the tie type and material, its breaking load, UV resistance, the eyelet spacing, and that every eyelet is to be tied.
Drawings
- Screen drawing: finished dimensions, hem detail, eyelet positions and spacing, reinforcement, and print area.
- Fixing drawing: how the screen is tied to the panel frame, top, bottom and sides, and whether it is fitted on the site side or the public side.
- Fence arrangement for the screened condition: stay spacing, ballast per stay, base type, and any gaps left between screens for wind relief or visibility at gates and corners.
Three Materials in Contact
A privacy or wind screen brings three groups of material into permanent contact on a temporary fence: the UV-stabilized polyethylene fabric, the fasteners that hold it (eyelets, ties, clips and hooks), and the galvanized tube and mesh behind it.
Chemical Compatibility of the Screen
Ultraviolet light and oxidation: controlled by stabilisers. Some site chemicals, notably sulphur- and halogen-containing agrochemicals and certain acidic pollutants, can deactivate the common hindered-amine stabilisers and shorten life.
Solvents and fuels: aromatic and chlorinated solvents, petrol and diesel swell polyethylene and extract additives. Splashes should be washed off; soaked fabric should be replaced.
Heat: hot work, exhausts and flood-lamps soften and shrink the fabric well below the temperatures that affect steel.
Printing inks and coatings: solvent-based inks must be confirmed as compatible by the screen supplier; adhesion on polyethylene is poor without surface treatment.
Samples
Printed sample: where branding is required, a printed section in the actual colours for approval in daylight.
Ties: a set of the ties to be supplied.
Receiving Inspection
On delivery, check a sample of screens from each batch: measure width and height, count and measure eyelet spacing, weigh one screen and compare with the stated mass per unit area, pull one eyelet by hand, and compare colour with the approved sample. Screens that differ from the approved sample in mass or eyelet spacing should be queried before they are installed, because both affect the wind behaviour on which the fence design was based.
Supplier Submittals
| Document | When |
|---|---|
| Technical data sheet | With offer |
| Weathering evidence | With offer |
| Stability statement for screened fence | With offer |
| Installation instructions | With delivery |
| Batch identification | With delivery |
The Crevice Behind the Screen
The most important interaction is neither galvanic nor strictly chemical.
Remove screens for storage: panels stacked wet with screens attached are prone to wet-storage staining.
Summary Checklist
With the offer: data sheet, fire report, weathering evidence, drawings, samples.
Before installation: receiving inspection passed; stays and ballast installed to the screened schedule before the screens are tied on.
In service: ties and hems inspected after strong wind; damaged screens removed, not left to flap.
Quote the frontage and side runs separately
The public frontage may need branding and privacy, while the side run can remain open. Mark those sections, the effect on sightlines and the intended fabric on the drawing. Ask for the fence configuration behind each section of fabric so you can compare packages on the same scope.
Frequently asked questions
What screen details help suppliers quote comparable products?
State finished sizes, coverage by fence run, fabric type, measured openness where specified, edge reinforcement and the proposed attachment points.
Who checks the fence before privacy screens are installed?
Have the person responsible for the fence commission a site-specific check of the screened configuration, including supports and wind exposure.
Related product and planning information
Privacy screens · Request a quote
Further reading · WorkSafe Victoria, Construction site security fencing
Further reading
Browse articles
Replacing Temporary Fence Privacy Screens: What to Inspect First
Check the fasteners, eyelets and hems before ordering replacement fabric. Damage at several adjacent points, repeated tears or movement of the fence merits a review of the complete screened line.

What to Include in a Temporary Construction Fencing Quote
Ask suppliers to quote the same marked-up perimeter, including gates, bases, clamps, bracing and any screening. A panel-only price leaves the biggest differences in scope unanswered.

Welded Mesh vs. Chain-Link Temporary Fence Panels
Choose the infill around the job and the fleet. Welded mesh gives the panel a rigid grid, while woven chain-link fabric flexes and relies on its ties and frame for support.
Google Search
Choose KINGCATS as a preferred source
Find our site in Google's source settings and confirm your choice. Availability is determined by Google.
Set preferred source