Industry insights

Galvanized Temporary Fence Panels: Pre-Galvanized or Hot-Dip After Fabrication?

The word “galvanized” can describe different production routes. Confirm whether zinc was applied to the strip before forming or to the finished assembly, and ask how seams, cut edges and welds are protected.

Two Routes to a Galvanized Frame

Pre-galvanized tube is roll-formed and seam-welded from strip that was galvanized continuously in the coil.

Hot-dip galvanized tube starts as uncoated ("black") structural or general-purpose tube, for example to EN 10219 or ASTM A500. It is galvanized by immersion in molten zinc, either as tube or, more usefully for fence panels, after the complete frame and mesh have been fabricated (ISO 1461 or ASTM A123).

Coating Mass and Thickness

Continuous coatings are specified by mass per unit area, summed over both faces.

These figures apply to undamaged flat surface.

Coverage: Where the Coating Is Missing

ZoneRisk if unprotected
Outside of seam weldRust line along the tube within months in wet conditions
Inside of seam weldInternal rust; staining at tube ends and drain points
Tube endsRust at ends; limited on thin walls
Mesh-to-frame weldsMany small rust spots; commonest complaint
Frame joint weldsRust at the most highly stressed points
Scuffs from forming and handlingMinor; zinc protects narrow scratches sacrificially

Appearance

A sound pre-galvanized surface is smooth and bright to light grey, with or without visible spangle depending on the line. Appearance is not a measure of protection, but certain features indicate a problem.

FeatureCause
Regular or minimised spangle; slight variation in brightnessNormal solidification of zinc
Light scuff marks along the tubeForming rolls
Dark or dull line along the seamSeam re-protection coating
Bare spots or pinholes on the strip surfacePoor wetting in the galvanizing line
White powdery depositWet-storage stain from damp stacking
Flaking or peeling at bendsExcessive alloy layer or poor adhesion

What "Pre-Galvanized" Means

The coating is therefore thin, uniform and smooth, and it is present on both the outside and the inside of the tube. It is also interrupted. The longitudinal seam weld burns it away on the tube mill, every cut exposes bare steel at the tube end, and every weld made by the panel manufacturer removes it locally.

Frame Strength in Bending

Diameter and wall thickness therefore deserve at least as much attention as steel grade.

What Is Excluded

ProductWhy excluded
Sheet and strip galvanized continuously, and tube made from it (pre-galvanized tube)Coated in continuous lines before forming
Wire for welded mesh and chain-link fabricCoated continuously as wire
Tube galvanized in automatic tube plantsSemi-continuous process with its own requirements
Threaded fastenersThread fit and centrifuging need specific rules
Duplex systems (paint or powder over galvanizing)ISO 1461 covers only the zinc layer; it notes that after-treatments and overcoating are outside its scope

Inspection Points

Inspection pointComment for temporary products
Appearance of significant surfacesSharp zinc spikes at drainage points must be removed: these products are handled by hand
Flux and ash residues; lumps of zincCheck inside tube ends and sockets
Colour and surface variationAppearance depends on steel composition; agree a sample if appearance matters
Coating thicknessMagnetic method; gravimetric method in dispute
Vent and drain holesCheck that holes are present, of adequate size, and free of blocking zinc
Fit of moving and mating partsCheck hinge pins, clamp bores, sockets and threads after galvanizing

What the Standard Covers

ISO 1461 specifies the general properties of coatings, and the test methods for them, applied by dipping fabricated iron and steel articles in molten zinc: the process often called batch, general or after-fabrication galvanizing. The article is made first and coated afterwards, so that all surfaces, edges, welds and, with proper venting, internal surfaces receive the coating.

What to Specify and Verify

  • Steel designation and standard for the strip or tube, with minimum yield strength. Avoid forming grades without a yield value where frame strength is required.
  • Tube dimensions: outside diameter, wall thickness and tolerances, measured on the steel excluding coating.
  • Mechanical test certificate for the tube: yield strength, tensile strength and elongation with the gauge length stated.
  • Galvanizing route: pre-galvanized with seam and weld repair, or hot-dip galvanized after fabrication, with the coating standard.

Information to Be Agreed

Significant surfaces: which surfaces are essential to appearance or function, by drawing or sample.

After-treatment: whether articles are to be left unpassivated because powder coating or painting will follow.

Inspection arrangements: where and by whom; how lots are defined.

Certificate: a statement of compliance with ISO 1461 for each delivery, with thickness results on request.

Sampling for Thickness

Thickness is checked on a control sample taken at random from each inspection lot. The standard gives the minimum number of articles according to the lot size.

Ask for a like-for-like coating comparison

When one offer says pre-galvanized and another says hot-dip galvanized after welding, request a drawing showing each coating stage and the surfaces covered. Compare tube section and steel grade separately. Record the agreed inspection method and approved repair for cut or welded areas on the order.

Frequently asked questions

How do I tell whether a quoted fence was galvanized before or after welding?

Ask for the process sequence for the wire mesh and the frame, plus the treatment of welds and cut edges. Request the written specification for the completed panel.

Is a zinc thickness figure enough to compare two fence quotes?

Compare the part measured, the test method, the applicable specification and the inspection lot. The same figure can describe different components.

Related product and planning information
Welded mesh panels · Quality control

Further reading · American Galvanizers Association, Batch Hot-Dip Galvanizing vs. Continuous Galvanizing

Share this article