Industry insights

Galvanized Temporary Gates: What to Check on the Finish at Delivery

Agree which areas of a temporary gate will be inspected and how coating thickness and repairs will be documented. Pay particular attention to hinge brackets, latch posts and surfaces that rub during operation.

Why the Finish of a Gate Is Inspected Differently

A mobile access gate carries the same finishes as the fence beside it: galvanizing, or galvanizing with a powder coating. It differs in how the finish is stressed.

Thickness

Thickness is measured with a magnetic gauge, adjusted on uncoated material of the same form. On a duplex finish the zinc is measured before powder coating so that the two layers can be reported separately.

LocationReason
Hinge stile, front and back, at each hingeHighest wear and load
Latch stile at the latch and at hand heightHandled at every operation
Wheel bracket and drop-bolt guideAbrasion and ground contact
Inside corners and recessesFaraday-cage areas

Adhesion

Adhesion is checked by the cross-cut test (ISO 2409 or ASTM D3359) on flat test panels coated with each batch, and periodically on a leaf.

At edges and welds: a firm scrape with a blunt blade at a sharp edge and across a weld toe. Coating that flakes ahead of the blade will chip in service.

After forming or adjustment: if hinges or brackets are adjusted or straightened after coating, the bent area is examined for cracking and lifting.

Defects

DefectConsequence in a gate
Missed or incomplete weldJoint has no strength; leaf racks
UndercutNotch in the thin wall at the weld toe; fatigue crack start
PorosityReduced section; rust bleeding through coating
CrackGrows in service; not acceptable at any size
Spatter and rough profileInjury hazard; poor coating coverage

Porosity

Porosity means discontinuities through the coating to the layer beneath: pinholes, craters, bare spots and cracks.

Visual Defects

ZoneSurfaces
APublic-facing faces of stiles and rails; hand-contact areas
BSite-facing faces; mesh; infill
CUndersides; inside of brackets; areas hidden in use
DefectCause
Bare spots; missed areasShielding; poor wetting; contact points
Sharp zinc spikes, drips; weld spatter under coatingDrainage; unprepared welds
Pinholes and cratersOutgassing
Jig marksHanging points
Scratches and chips from handlingAfter coating

Visual inspection needs defined conditions, or it becomes a matter of opinion. Three things are fixed: the lighting, the viewing distance, and the classification of surfaces.

When Field Repair Is Needed

Galvanized coatings on temporary fencing, hoarding and barriers are damaged in three ways: by welding carried out after galvanizing, by mechanical damage in handling and use, and by cutting or drilling on site.

Acceptance Checks

CheckMethod
CoverageVisual
Dry film thicknessMagnetic thickness gauge, after cure; at least three readings per repair on a sample of repairs
AdhesionFirm scrape with a blunt knife at the edge of the repair; or cross-cut on test areas
CureThumbnail or solvent rub as the data sheet describes
AppearanceVisual
RecordRepair log

Surface Preparation

Preparation decides the life of the repair. Zinc-rich paint works only if its zinc particles are in electrical contact with bright steel; solder and sprayed zinc bond only to clean metal. The area prepared must extend into the sound galvanizing around the damage so that the repair overlaps it.

Remove contaminants first: oil, grease and soluble salts are washed off before mechanical cleaning, or they are spread and driven into the surface.

What to Expect of a Repair

It is softer, so it wears through at contact points; it is a paint, so it ages in sunlight; and its sacrificial action is weaker than that of solid zinc. Repairs should therefore be listed for inspection, and re-coated when they wear or when rust staining appears at their edges.

Sampling, Records and Release

Records: leaf serial or lot, coating batch, pretreatment and oven records, thickness readings with locations, adhesion and cure results, defects found and repairs made, inspector and date.

Every leaf: visual inspection of all zones; thickness at the hinge and latch stiles; touch-up of any defects found, with re-inspection.

Each coating batch: full thickness survey of one leaf; cross-cut on test panels; cure test as the powder supplier specifies.

Periodically: wet adhesion; porosity test on a leaf; comparison of colour and gloss with the retained reference.

Separate a transport scuff from a functional defect

A mark on a visible rail and a raised burr at the latch affect the gate differently. Record the location and whether the protection or movement is affected. Ask for the approved repair method, then inspect the finish and operate the gate again after the repair.

Frequently asked questions

What parts of a galvanized temporary gate should be checked on delivery?

Inspect welds, cut edges and visible coating damage. In a trial assembly, check hinges, latch and moving clearances against the agreed drawing.

How should a zinc burr near a latch be handled?

Record the location, affected lot and effect on operation. Hold the gate for an agreed repair or replacement and check the coating and latch again before acceptance.

Related product and planning information
Temporary fence gates · Quality control

Share this article